• In Bangalore it is now mandatory for all complexes with 20 or more flats to set up STP within 3 months
  • Big Relief to Bangalore Apartment Owners- MoEF dilutes Discharge standards on 13-10-2017 to make it easy for STP owners
  • Micro STPs for 20 to 30 Apartments- Faster delivery- Prices start at 5.0 lakhs
  • BBMP issues guidelines on setting up STP in apartments in Bangalore. Details in this website
  • Indus launches 'Zero Discharge Sewage Treatment Plants' & Instant Sewage Treatment Plants 'e-STP'
  • Effluent Treatment Plants for Restaurant, Car Wash & Diary Industry
  • We have launched 'Zero Discharge Sewage Treatment Plant' for 100% recycle of Sewage
  • Channel Associates wanted in All State Capitals

High Quality low cost ETP solutions
Home -  High quality re-use plants

    High Quality Re-use Plants

    Suitable for toilet flushing, floor wash, car wash, boiler feed etc.
    Highest quality treated sewage is produced by using membrane technology. 
     

    What is ultra-filtration

    Ultra-filtration (UF) is a type of membrane filtration in which hydrostatic pressure forces a liquid against a semi-permeable membrane. A semi-permeable membrane is a thin layer of material capable of separating substances when a driving force is applied across the membrane. Once considered a viable technology only for desalination, membrane processes are increasingly employed for removal of bacteria and other microorganisms, particulate material, and natural organic material, which can impart color, tastes, and odors to the water and react with disinfectants to form disinfection byproducts (DBP). 

    Ultra-filtration uses hollow fibers of membrane material and the feed water flows either inside the shell, or in the lumen of the fibers. Suspended solids and solutes of high molecular weight are retained, while water and low molecular weight solutes pass through the membrane. Ultra-filtration is similar to reverse osmosis, except in terms of the size of the molecules it retains. When strategically combined with other purification technologies in a complete water system, UF is ideal for the removal of colloids, proteins, bacteria, pyrogens, proteins, and macromolecules larger than the membrane pore size from water. The primary removal mechanism is size exclusion, though surface chemistry of the particles or the membrane may affect the purification efficiency.
     

    Major advantages of low-pressure UF membrane processes:

    • Chemical free (coagulants, flocculates, disinfectants, pH adjustment)

    • 100% Colloidal / Particle removal

    • Bacteria & Virus removal

    • Low Pressure operation

    • Low energy consumption

    • Good and constant quality of the treated water in terms of particle and microbial removal ensuring

      consistent treated water quality

    • Compact design / Small foot print

    • Fully automatic operation

    UF is used to remove essentially all colloidal particles (0.001 to 1.0 microns) from water and some of the largest dissolved contaminants. The pore size in a UF membrane is mainly responsible for determining the type and size of contaminants removed. In general, membrane pores range in size from 0.005 to 0.1 micron. Molecular weight cutoff (MWCO) is a rough measurement of the size of contaminants removed by a given UF membrane. A 100,000 MWCO UF membrane means that when water containing particles bigger than molecular weight of around 100,000 Daltons is fed to the UF unit, nearly all of the compound will not pass through the membrane.

    Range: 25 KLD
    Feed Pumps : One duty
    Feed Pump capacity : 0.375 Kw
    Backwash Pump capacity : 1.2Kw
    SS 304 CIP Pump capacity : 0.375 Kw
    Pumps Make : DAB / Grundfos / Eq
    Dual Media Filter : 16x65
    Activated Carbon Filter : 16x65
    Inlet / outlet size : 3/4”
    Maximum hourly flow : 1500 Lts per hour
    Type of valves : Automatic
    UF Membrane Size :  
    UF MWCO : 50 KD
    Flow Configuration : Inside out- Dead End
    Origin of UF Membrane : Imported
    Chlorine Tolerance : Up to 5 PPM continuous
    Control Panel : Fully automatic with micro-processor
    Additional accessories : Tank level sensors for raw & treated water

     

    Range: 26-50 KLD
    Feed Pumps : One duty
    Feed Pump capacity : 0.8 Kw
    Backwash Pump capacity : 1.5Kw
    SS 304 CIP Pump capacity : 0.8 Kw
    Pumps Make : DAB / Grundfos / Eq
    Dual Media Filter : 24x72
    Activated Carbon Filter : 24x72
    Inlet / outlet size : 1”
    Maximum hourly flow : 2500 Lts per hour
    Type of valves : Automatic
    UF Membrane Size :  
    UF MWCO : 50 KD
    Flow Configuration : Inside out- Dead End
    Origin of UF Membrane : Imported
    Chlorine Tolerance : Up to 5 PPM continuous
    Control Panel : Fully automatic with micro-processor
    Additional accessories : Tank level sensors for raw & treated water

     

    Range: 100 KLD
    Feed Pumps : One duty
    Feed Pump capacity : 1Kw
    Backwash Pump capacity : 2.2Kw
    SS 304 CIP Pump capacity : 1.0 Kw
    Pumps Make : DAB / Grundfos / Eq
    Dual Media Filter : 36x72
    Activated Carbon Filter : 36x72
    Inlet / outlet size : 1.5”
    Maximum hourly flow : 2500 Lts per hour
    Type of valves : Automatic
    UF Membrane Size :  
    UF MWCO : 50 KD
    Flow Configuration : Inside out- Dead End
    Origin of UF Membrane : Imported
    Chlorine Tolerance : Up to 5 PPM continuous
    Control Panel : Fully automatic with micro-processor
    Additional accessories : Tank level sensors for raw & treated water

     

    Custom Designed

    We will design the recycling plant to suit your flow and requirement

    Feed Pumps : As per requirement
    Feed Pump capacity : As per requirement
    Backwash Pump capacity : As per requirement
    SS 304 CIP Pump capacity : Will be designed as per requirement
    Pumps Make : DAB / Grundfos / Eq
    Dual Media Filter : As per requirement
    Activated Carbon Filter : As per requirement
    Inlet / outlet size : Will be designed as per requirement
    Maximum hourly flow : Customer defined
    Type of valves : Automatic
    UF Membrane Size : As required
    UF MWCO : 50 KD
    Chlorine Tolerance : Up to 5 PPM continuous
    Control Panel : Fully automatic with micro-processor
    Additional accessories : Tank level sensors for raw & treated water